Enumeration
GioDBusError
since: 2.26
Members
-
G_DBUS_ERROR_FAILED -
A generic error; “something went wrong” - see the error message for more.
- Value:
0 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NO_MEMORY -
There was not enough memory to complete an operation.
- Value:
1 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SERVICE_UNKNOWN -
The bus doesn’t know how to launch a service to supply the bus name you wanted.
- Value:
2 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NAME_HAS_NO_OWNER -
The bus name you referenced doesn’t exist (i.e. no application owns it).
- Value:
3 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NO_REPLY -
No reply to a message expecting one, usually means a timeout occurred.
- Value:
4 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_IO_ERROR -
Something went wrong reading or writing to a socket, for example.
- Value:
5 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_BAD_ADDRESS -
A D-Bus bus address was malformed.
- Value:
6 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NOT_SUPPORTED -
Requested operation isn’t supported (like ENOSYS on UNIX).
- Value:
7 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_LIMITS_EXCEEDED -
Some limited resource is exhausted.
- Value:
8 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_ACCESS_DENIED -
Security restrictions don’t allow doing what you’re trying to do.
- Value:
9 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_AUTH_FAILED -
Authentication didn’t work.
- Value:
10 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NO_SERVER -
Unable to connect to server (probably caused by ECONNREFUSED on a socket).
- Value:
11 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_TIMEOUT -
Certain timeout errors, possibly ETIMEDOUT on a socket. Note that
G_DBUS_ERROR_NO_REPLYis used for message reply timeouts. Warning: this is confusingly-named given thatG_DBUS_ERROR_TIMED_OUTalso exists. We can’t fix it for compatibility reasons so just be careful.- Value:
12 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_NO_NETWORK -
No network access (probably ENETUNREACH on a socket).
- Value:
13 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_ADDRESS_IN_USE -
Can’t bind a socket since its address is in use (i.e. EADDRINUSE).
- Value:
14 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_DISCONNECTED -
The connection is disconnected and you’re trying to use it.
- Value:
15 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_INVALID_ARGS -
Invalid arguments passed to a method call.
- Value:
16 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_FILE_NOT_FOUND -
Missing file.
- Value:
17 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_FILE_EXISTS -
Existing file and the operation you’re using does not silently overwrite.
- Value:
18 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_UNKNOWN_METHOD -
Method name you invoked isn’t known by the object you invoked it on.
- Value:
19 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_TIMED_OUT -
Certain timeout errors, e.g. while starting a service. Warning: this is confusingly-named given that
G_DBUS_ERROR_TIMEOUTalso exists. We can’t fix it for compatibility reasons so just be careful.- Value:
20 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_MATCH_RULE_NOT_FOUND -
Tried to remove or modify a match rule that didn’t exist.
- Value:
21 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_MATCH_RULE_INVALID -
The match rule isn’t syntactically valid.
- Value:
22 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_EXEC_FAILED -
While starting a new process, the
exec()call failed.- Value:
23 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_FORK_FAILED -
While starting a new process, the
fork()call failed.- Value:
24 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_CHILD_EXITED -
While starting a new process, the child exited with a status code.
- Value:
25 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_CHILD_SIGNALED -
While starting a new process, the child exited on a signal.
- Value:
26 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_FAILED -
While starting a new process, something went wrong.
- Value:
27 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_SETUP_FAILED -
We failed to setup the environment correctly.
- Value:
28 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_CONFIG_INVALID -
We failed to setup the config parser correctly.
- Value:
29 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_SERVICE_INVALID -
Bus name was not valid.
- Value:
30 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_SERVICE_NOT_FOUND -
Service file not found in system-services directory.
- Value:
31 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_PERMISSIONS_INVALID -
Permissions are incorrect on the setuid helper.
- Value:
32 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_FILE_INVALID -
Service file invalid (Name, User or Exec missing).
- Value:
33 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SPAWN_NO_MEMORY -
Tried to get a UNIX process ID and it wasn’t available.
- Value:
34 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_UNIX_PROCESS_ID_UNKNOWN -
Tried to get a UNIX process ID and it wasn’t available.
- Value:
35 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_INVALID_SIGNATURE -
A type signature is not valid.
- Value:
36 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_INVALID_FILE_CONTENT -
A file contains invalid syntax or is otherwise broken.
- Value:
37 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_SELINUX_SECURITY_CONTEXT_UNKNOWN -
Asked for SELinux security context and it wasn’t available.
- Value:
38 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_ADT_AUDIT_DATA_UNKNOWN -
Asked for ADT audit data and it wasn’t available.
- Value:
39 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_OBJECT_PATH_IN_USE -
There’s already an object with the requested object path.
- Value:
40 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_UNKNOWN_OBJECT -
Object you invoked a method on isn’t known. Since 2.42.
- Value:
41 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_UNKNOWN_INTERFACE -
Interface you invoked a method on isn’t known by the object. Since 2.42.
- Value:
42 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_UNKNOWN_PROPERTY -
Property you tried to access isn’t known by the object. Since 2.42.
- Value:
43 - Available since: 2.26
- Value:
-
G_DBUS_ERROR_PROPERTY_READ_ONLY -
Property you tried to set is read-only. Since 2.42.
- Value:
44 - Available since: 2.26
- Value:
Type functions
g_dbus_error_encode_gerror
Creates a D-Bus error name to use for error. If error matches
a registered error (cf. g_dbus_error_register_error()), the corresponding
D-Bus error name will be returned.
since: 2.26
g_dbus_error_is_remote_error
Checks if error represents an error received via D-Bus from a remote peer. If so, use g_dbus_error_get_remote_error() to get the name of the error.
since: 2.26
g_dbus_error_new_for_dbus_error
Creates a GError based on the contents of dbus_error_name and
dbus_error_message.
since: 2.26
g_dbus_error_register_error
Creates an association to map between dbus_error_name and
GErrors specified by error_domain and error_code.
since: 2.26
g_dbus_error_register_error_domain
Helper function for associating a GError error domain with D-Bus error names.
since: 2.26
g_dbus_error_set_dbus_error
Does nothing if error is NULL. Otherwise sets *error to
a new GError created with g_dbus_error_new_for_dbus_error()
with dbus_error_message prepend with format (unless NULL).
since: 2.26
g_dbus_error_set_dbus_error_valist
Like g_dbus_error_set_dbus_error() but intended for language bindings.
since: 2.26
g_dbus_error_strip_remote_error
Looks for extra information in the error message used to recover
the D-Bus error name and strips it if found. If stripped, the
message field in error will correspond exactly to what was
received on the wire.
since: 2.26
g_dbus_error_unregister_error
Destroys an association previously set up with g_dbus_error_register_error().
since: 2.26